Since 2010, our professional crew installs DITRA-HEAT for even warmth under tile — combining electric heating with uncoupling for a durable assembly. We plan thermostat locations, sensors, and keep-out zones, then set tile over a flat, properly primed substrate for comfort that lasts. Try our cost calculator for an instant estimate or call us now!
Radiant heating requires careful layout and installation.
We follow a detailed 5-step process to ensure even warmth, safe operation, and durable tile finishes across every project.
Room mapping, keep-
out zones,
thermostat/sensor
locations.
We start with careful room assessment and comprehensive planning, including keep-out zone mapping around fixtures, optimal thermostat placement, and sensor routing for accurate temperature control.
Prime/flatten to large-
format tolerances for
coverage and feel.
Surface preparation to strict flatness tolerances with primer application and leveling compounds, ensuring optimal coverage and comfortable feel underfoot for heated floor systems.
Install DITRA-HEAT; lay
cable per plan.
DITRA-HEAT membrane installation with precise cable layout according to our plan, ensuring even spacing, proper keep-out zones, and sensor placement for uniform heating.
Directional trowelling;
movement joints at
plane changes.
Professional tile installation with directional trowelling over the heating system, proper adhesive coverage, and movement joints at all plane changes for long-term durability.
Sensor test, thermostat
setup, care notes.
Complete system commissioning with sensor testing, thermostat programming, and comprehensive handover including operation instructions and maintenance care notes.
Smart controls and optimal placement for maximum comfort and efficiency.
Smart controls and sensors that optimize energy use without sacrificing comfort.
Programmable schedules that match your daily routine for comfort and efficiency.
Smart controls and sensors that optimize energy use without sacrificing comfort.
Get a detailed timeline and estimate for your specific DITRA-HEAT project.
Our process ensures warm, comfortable results and your peace of mind.
See how we plan cable spacing, keep-out zones, and sensor paths for different room types.
Strategic cable spacing tuned for cooking area with clear paths around cabinets and appliances.
Targeted heat zones at entry points for quick drying and comfort during weather changes.
Beyond the initial wow factor, these are the lasting qualities that make your floors a joy to use every single day.
Cable spacing tuned for uniform temperatures.
Uncoupling helps the tile layer manage movement.
Colour-matched sealants at plane changes and tidy transitions.
Programmable thermostats with floor sensors for comfort and efficiency.
Every tile placed with millimetre precision for
stunning, lasting results. Our attention to detail
ensures perfect alignment, consistent spacing, and
professional-grade finishing that stands the test of
time.
Perfect substrate preparation
Consistent spacing & layout
Waterproof protection system
We work with DITRA-HEAT membrane systems, Mapei mortars suited to heating, and Laticrete sealants so all components are designed to perform together in heated applications. That means fewer surprises and finishes that last.
Waterproofing Systems
Adhesives & Grouts
Installation Products
Tile Supplier
Innovative Tile
Professional Tools
Flooring & Tile
Tile Tools
Tile Retailer
Flooring Supplies
Premium Surfaces
Natural Stone
Our partnerships with industry leaders ensure every heated floor installation
uses compatible, proven systems for lasting warmth and performance.
See some of our recent tile installation projects across Toronto, the GTA, and beyond!
Join our satisfied customers across The GTA. Get a detailed estimate for your DITRA-HEAT heated floor project.
Watch our customers describe their tile installation experience and see the quality results we deliver across Ontario.
From cable layout planning to thermostat placement, this complete guide covers what every homeowner needs to know about DITRA-HEAT heated floor installation in Toronto & the GTA.
DITRA-HEAT combines electric heating cables with uncoupling membrane technology, creating both comfortable warmth and long-term tile assembly protection. The system accommodates in-plane movement from seasonal expansion while delivering consistent surface temperatures. Professional installation ensures proper cable spacing, accurate sensor placement, and optimal thermostat positioning for years of reliable comfort.
Consistent spacing prevents hot/cold banding; avoid loops under fixed cabinetry. We map keep-out zones around toilets, vanities, and permanent fixtures, then calculate optimal cable spacing for uniform heat distribution. Proper planning prevents overheating in concentrated areas while ensuring adequate warmth throughout the heated zone.
A flatter base improves coverage and the feel underfoot. We prepare substrates to strict flatness tolerances, ensuring the heating cables sit properly and tile installation achieves consistent coverage. Proper surface preparation eliminates high spots that could damage cables and low spots that create uncomfortable temperature variations.
Accurate readings and convenient access improve comfort. Floor sensors are positioned in the center of the heating field, away from exterior walls and direct heat sources. Thermostats are mounted at convenient heights near room entrances, avoiding locations with temperature fluctuations that could affect system performance.
Helps manage in-plane movement for long-term durability. The DITRA-HEAT membrane’s uncoupling layer allows the tile assembly to move independently from the substrate, reducing stress that could cause tile cracking. This protection is especially valuable in heated applications where thermal expansion is a consideration.
Waterproof continuity and soft joints at changes of plane. When installing heated floors in bathrooms, we integrate waterproofing systems with the heating assembly. Proper detailing at penetrations, corners, and plane changes ensures moisture protection while maintaining heating system integrity.
Gradual ramp-up temperatures; pH-neutral cleaning. During commissioning, we program thermostats for gentle temperature increases and establish maintenance schedules. Regular cleaning with pH-neutral products preserves both tile and grout appearance while protecting the heating system components beneath.
Our team is WSIB/insured, and follows manufacturer instructions for membranes, cables, and mortars. Uncoupling membranes and movement joints are used appropriately to protect the assembly.
Free tile cost calculator with instant estimates based on your specific project requirements.
Waterproofing expertise
Trusted 15+ years
Proven client satisfaction
Safety & Compliance
+ 100km radius from Toronto
Start with our Cost Calculator to get a quick estimate or call us now!
Get answers to common questions about DITRA-HEAT heated floor installation, energy efficiency, and our services across Toronto & the GTA.
Electric heating cables or mats sit beneath new tile. The system warms the substrate, which radiates gentle, even heat through the tile surface. A floor sensor and thermostat manage temperature and schedules for consistent comfort without moving air.
Yes when specified correctly. We use waterproofing where required, position the floor sensor appropriately, and connect a GFCI-protected thermostat. Details follow tile standards and electrical code for a sealed system beneath the finished tile.
The heating layer and membrane typically add only a few millimetres before tile. Exact build-up depends on cable or mat type, membrane choice, mortar coverage, and tile thickness. We plan transitions so thresholds and fixtures finish cleanly.
Flat, clean, properly secured substrates are key. We address movement joints, levelling, and uncoupling as needed, and verify insulation or thermal breaks where appropriate. Good prep supports even heat, reliable tiling, and sensor accuracy.
Often in smaller, well-insulated rooms. In larger spaces, floor heat adds comfort and can supplement other heating. We size zones and suggest insulation strategies to align with comfort goals and room characteristics.
Programmable or Wi-Fi thermostats manage temperature, schedules, and zones. Many support app control and voice assistants. We calibrate the floor sensor and set profiles so warmth meets routine use while prioritizing efficiency.
Radiant systems target surfaces and occupants, reducing stratification. Zoning, schedules, and adequate insulation can lower run time. Actual consumption depends on room size, construction, coverage, and chosen setpoints.
Minimal. The system has no active moving parts. Clean tile and grout as usual and keep the thermostat settings appropriate. If a fault appears, resistance testing and thermal imaging help locate issues for targeted repair.
Timelines depend on room size, tile layout, substrate prep, and cure times.
Share photos, approximate square footage, and a brief note about the room in an email. Use our calculator or form, or call. We review site conditions, propose a layout and thermostat, and schedule work across Toronto and nearby communities (~100 km).